Recent Changes - Search:

radlab home

radlab support

generic HFDR

principles
hardware
software
production
documents
pictures

know-how

projects

CNMI-Guam
CWA
IFREMER
IHMT
ISMER
NAMR
PACIOOS
TORI
UABC
UHHilo
UP-MSI
WHOI

old projects

MEC
OGS
UAF

.

PA120

Notes

  • TOMCO serial number xxxx

Power Supply Measurements

AC voltage setting:
DC voltage (V): (should be about 24.5 V under load, adjust otherwise)
Ammeter reading (A):
UPS power load w/ 2dBm input(W):

Signal Measurements

  • RF power meter: Mini Circuits PWR-SEN-6G+ USB power sensor
  • internal attenuator set at 0 dBm
  • power meter 50 dBm offset applied for measurements at rear panel connectors
  • 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
LocationMeter Reading (dBm)Rabbit Reading (dBm)Comments
IN connector   
FWD connector   
RFL connector   
OUT connector   

Temperature Measurements

  • temperature meter: DM6802B Digital Thermometer
LocationMeter Reading (deg C)Rabbit Reading (deg C)Comments 
BTC   
MCI   
AMB   

Spectrum Analyzer Images

Input Signal

At FWD connector

At RFL connector

At OUT connector

Edit - History - Print - Recent Changes - Search
Page last modified on November 15, 2012, at 02:02 AM