PA 1-17
Updated 12/04/2017
Test Frequency : 27.5 MHz
TOMCO serial number 18486 0.5-150 MHz (removed)
WERLATONE serial number 109531 1-50 MHz
FILTER none
Settings
- AUTO DHCP - ok
- FRONT LED - ok; when no load, LED OFF - ok
- default db in = 2dBm
Power Supply Measurements
AC voltage setting: 115V
DC voltage (V): 26.5
Ammeter reading (A):
UPS power load w/ 2dBm input(W):
Signal Measurements
- RF power meter: Mini Circuits PWR-SEN-6GHS USB power sensor
- internal attenuator set at 0 dBm
- power meter 50 dBm offset applied for measurements at rear panel connectors
- 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
| Location | Meter Reading (dBm) | Rabbit Reading (dBm) | Comments | |
| IN connector | +2.00 | 1.6 | |
| FWD connector | ---- | ---- | |
| RFL connector | ---- | ---- | |
| OUT connector | +46.34 | 47.5 | stable @ 0dB |
Temperature Measurements
- temperature meter: DM6802B Digital Thermometer
| Location | Meter Reading (deg C) | Rabbit Reading (deg C) | Comments | |
| BTC | 41.6 | 40.0 | |
| MCI | 24.6 | 21.8 | |
| AMB | 26.0 | 25.5 | |
Spectrum Analyzer Images
Input Signal
At FWD connector
At RFL connector
At OUT connector