Notes
- TOMCO serial number xxxx
- Configured for 26 MHz
Power Supply Measurements
AC voltage setting: 115
DC voltage (V): 24.3 (should be about 24.5 V under load, adjust otherwise)
Ammeter reading (A): 1.5
UPS power load w/ 2dBm input(W): N/A
Signal Measurements
- RF power meter: Mini Circuits PWR-SEN-6G+ USB power sensor
- internal attenuator set at 0 dBm
- power meter 50 dBm offset applied for measurements at rear panel connectors
- 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
Location | Meter Reading (dBm) | Rabbit Reading (dBm) | Comments | |
IN connector | 1.95 | 1.7 | |
FWD connector | | | |
RFL connector | | | |
OUT connector | 46.3 | 46.3 | |
Temperature Measurements
- temperature meter: DM6802B Digital Thermometer
Location | Meter Reading (deg C) | Rabbit Reading (deg C) | Comments | |
BTC | | 27.3 | |
MCI | | 23.3 | |
AMB | | 28.4 | |
Spectrum Analyzer Images
Input Signal
At FWD connector
At RFL connector
At OUT connector